Year- round classes customized to fit the EXACT RELAYS & RTUs on your site
Modules equipped with
integrated POWER SUPPLY
Mobile lab modules make it easy to conduct classes AT ANY LOCATION
These instructional labs will help you understand all key elements & principles of the electrical protection system, along with various protection philosophies and design standards. Emphasis is given on the correct methodology to test, verify, troubleshoot, and commission any P&C/ SCADA system. With real-world test setups, the training provided in the lab to engineers and field service technologists will set them apart from the competition.
The advanced protection courses include end-to-end testing methodologies used for commissioning communication-enabled distance protection schemes.
A variety of functional tests, common issues, and troubleshooting techniques related to line protection schemes are also included in the course.
Protection & Control Hands-on Lab Courses
-
Theoretical Lessons On All Protection Types
-
Custom Hands-on lab exercises
-
Vendor-Neutral with Relays
-
On-Demand Relay Training on Specific Relays
-
On-site Training With Protection Modules
-
Emphasis on real-world testing
-
Troubleshooting methods
SCADA Hands-on
Lab Courses
-
Common SCADA Architectures
-
Hands-on Training on SCADA Architecture
-
SEL RTAC Line
-
Eaton SMP Line
-
-
Emphasis on Relay/IED to RTU Interfaces
-
Hands-on Training of Common Protocols
-
Hands-on Training on Networking Equipment
most REQUESTED COURSES
Our courses below are led by subject matter experts in the electrical services field, who bring years of hands-on experience. Below are the most popular courses requested by personnel ranging from new graduates to experienced operators in the field.
Motor Protection
System Training
-
Undervoltage Protection (27)
-
UnderPower/UnderCurrent (37)
-
Bearing RTD Temp (38)
-
Current Unbalance (46)
-
Acceleration Protection (48)
-
Thermal Protection (49)
-
Time Overcurrent (51)
-
Definite Time Overcurrent (50)
-
Overvoltage Protection (59)
-
Start Inhibit
-
Mechanical Jam
Transformer Protection
System Training
-
Volts/Hz Protection (24)
-
Undervoltage Protection (27)
-
Thermal Overload (49)
-
Time Overcurrent (51)
-
Time Overcurrent (50)
-
Overvoltage Protection (59)
-
Frequency Protection (81)
-
Differential Protection (87)
Generator Protection
System Training
-
Phase Distance Backup (21)
-
Volts/Hz Protection (24)
-
Sync Check (25)
-
Undervoltage Protection (27)
-
3rd Harmonic U/V (27TH)
-
Directional Power (32)
-
Loss of Field (40)
-
Generator Unbalance (46)
-
Thermal Overload (49)
-
Voltage-Time Overcurrent (51V)
-
Definite Time Overcurrent (50)
Line Protection
System Training
-
Phase & Ground Distance Protection (21)
-
Line Differential Protection (87L)
-
Auto-Reclose (78)
-
Communication Enabled Protection Schemes
-
POTT (Permissive Overreach Transfer Trip)
-
PUTT (Permissive Underreach Transfer Trip)
-
DCB (Directional Blocking Scheme)
-
Weak Infeed / Echo Logic
-
Feeder Protection
System Training
-
Sync Check Function (25)
-
Undervoltage Protection (27)
-
Directional Power Protection (32)
-
Time Overcurrent Protection (51)
-
Time Overcurrent Protection (50)
-
Overvoltage Protection (59)
-
Direction Overcurrent (67)
-
Frequency Protection (81)
Bus Protection
System Training
-
Breaker Failure (50BF)
-
Low Impedance Differential (87)
-
High Impedance Differential (87Z)